Product Parameters
OLFLEX FD 891PVC Power Towline Cable
Cable ConstructionDesign:acc. to UL AWM Style 20886, CSA C22.2 No. 210-15 and based on EN 50525-2-51 resp. VDE 0285-525-2-51
Certification:UL AWM Style 20886 (File No. E503806)
Conductor:extra fine wire strands of bare copper acc. to IEC 60228 resp. VDE 0295, class 6
Insulation:PVC
Outer sheath:PVC
Taping:non-woven wrapping
Core identification code:acc. to VDE 0293-1, with or without GN/YE ground conductorblack cores with white numbers acc. to DIN EN 50334 resp. VDE 0293-334
Rated voltage:U₀ / U: 300 / 500 V
UL/CSA: 600 V
Test voltage : core / core:4000 V AC
Minimum bending radius:flexing up to 3m travel distance (horizontal, self supporting):up from10 x cable diameter
flexing up to 10m travel distance (horizontal, sliding):up from 12 x cable diameter
Temperature range :flexing (VDE):-5C up to +70 C max. conductor temp.
flexing (UL/CSA):-5 C up to +90 C max. conductor temp.
fixed installation (VDE):-40 C up to +80 C max. conductor temp.
fixed installation(UL/CSA): -40 Cup to +90 C max. conductor temp.
Flammabilityflame retardand acc. to IEC 60332-1-2 resp.VDE 0482-332-1-2
UL: vertical flame test VW-1
Oil resistanceacc. to EN 50363-4-1 resp. VDE 0207-363-4-1, TM5
UL: 80C rating acc. to UL 758
UV-resistance :acc. to EN 50525-1 (VDE 0285-525-1) cable with black sheath are suitable forpermanent outdoor use.
Testsacc. to IEC 60811 resp. VDE 0473 part 811, EN 50395, EN 50396, UL 1581 and CSA C22.2
Application
OLFLEXFD 891 cables are high flexible, oil-resistant cables for power chains for the European, Northern American and Canadian market.They are designed for flexible use as well as for fixed installation subject to medium mechanical load conditions.They are also suitable for use in dry, damp or wet areas.They are suitable for outdoor use if the indicated temperature range is observed.
OLFLEX FD 891 are increased resistant to oils and at room temperature largely resistant to acids and alkalis.They are suitable for linear, automated movements. The maximum tensile load is 15 N/mm2 of conductor cross-section during installation and operation. Compulsory guidance is not permitted.
Application range:
power chains or moving machine parts, suitable for use in measuring, control and regulating circuits, assembly lines, production lines, in all kinds of machines, machine tools, plant engineering.




Characteristics
1. Flame retardancy: UL/CSA: VW-1, FT 1IEC/EN: 60332-1-2
2. Low viscosity surface
3.Oil resistant
Advantage
1. High cost performance ratio2. Fine, light, no inner sheath3. Multiple Standard Certification, Reduce Inventory Type and Save Cost4. Certified by Manufacturers of Export Machinery, Equipment and Equipment of the United States and Canada


Product Details Show







Main Products

ANRBT900P
Flexible anti-twist robot shielded cable

ANF8001
High speed flexible towline cable

ANF9012
PUR double sheathed copper mesh shielded towline cable

H05VV5-F
Ultra-flexible PVC oil resistant control cable

NYSLYCY
Transparent sheathed copper mesh shielded control cable

LIYCY-CY
PVC insulated tinned copper wire double shielded data cable